Determine the strenght of the connection, quantify how many Newton the connection needs to hold
With the Newton value, you can determine the series:
Series
Force in Newton
Applications
5F
670N
Light Duty
99F
700N
Light Duty
50F
900N
Light Duty
2600/2700
1330N
Medium Duty
50F
3700N
Medium Duty
4002
4700N
Medium Duty
991S
10000N
Heavy duty
You take the catalogue at the page of the series and look for receptacles.
Choose here the receptacle that best fits to your application.
Remember the "type-number" of the receptacle.
With the help of the thickness of the plate and the frame and the receptacle number you can determine the correct formula on the first page, you arrive to a certain "G" value. Usually G = P + F
You choose the correct stud
Once the stud chosen, you can now determine the part number. On the place of the "star" = "*" you fill in the G-value.
You choose the retaining washer
Dependent on the series you can choose also to take a grommet, but this had an influence on the G-value
You are now ready to determine the quantity of pieces and to forward the correct part numbers